^LT
^LT

^LT

The
^LT
command moves the entire label format a maximum of 120 dot rows up or down from its current position, in relation to the top edge of the label. A negative value moves the format towards the top of the label; a positive value moves the format away from the top of the label.

Label Top

This command can be used to fine-tune the position of the finished label without having to change any of the existing parameters.
For some printer models, it is possible to request a negative value large enough to cause the media to backup into the printer and become unthreaded from the platen. This condition can result in a printer error or unpredictable results.
Format:
^LTx
Parameters
Details
x =
label top (in dot rows)
Values:
HC100:
0
to
120
XiIIIPlus 600dpi:
-240 to 240
All other Zebra printers:
-120
to
120
Default:
a value must be specified or the command is ignored
Comments:
The Accepted Value range for
x
might be smaller depending on the printer platform.
The Label Top value shown on the front panel of the printer is double the value used in the ZPL format.
The
^LT
command does not change the media rest position.