Listing the ZS300 Sensors
Listing the ZS300 Sensors

Listing the ZS300 Sensors

Before performing the following steps, at least one ZS300 Sensor must be enrolled.
  1. Click
    Authorize
    and enter your Client Key.
  2. Click
    Close
    .
  3. Expand the GET/devices/environmental-sensors method screen.
  4. Click
    Try It Out
    .
  5. In the page number field, enter 0.
  6. Enter 1 in the page size field. If more than one sensor is enrolled, enter the appropriate number.
  7. Enter the serial number of the Sensor in the text filter field.
  8. Delete the default values in the
    task_id, enrolled_after
    and
    enrolled_before
    fields if those are not needed.
  9. Click
    Execute
    . If successful, a response body with an HTTP Status Code of 200 is returned. A JSON body is included in the response which contains details of the currently enrolled Sensor.
    Occasionally, the 327.67 temperature reading may appear in the Last Temperature field. It is an invalid reading. When a sensor comes out from the deep sleep, it takes up to a minute before it starts sampling. During this time, the sensor doesn't have a valid temperature, so a value of 7FFF is used which produces the temperature reading of 327.67.
  10. Save the ID of the Sensor for the next step.