Naredbe za programiranje spremnika s vrpcom

Naredbe za programiranje spremnika s vrpcom

Pisač sa spremnikom s vrpcom nudi nekoliko naredbi za Set Get Do (SGD) programiranje kako bi se omogućila upotreba spremnika s vrpcom.
Slijede primjeri SGD naredbi za spremnik s vrpcom.
! U1 getvar "device.feature.ribbon_cartridge" ! U1 getvar "ribbon.cartridge.part_number" ! U1 getvar "ribbon.cartridge.authenticated" ! U1 getvar "ribbon.cartridge.length_remaining" ! U1 getvar "ribbon.cartridge.serial_number" ! U1 getvar "ribbon.cartridge.width" ! U1 getvar "ribbon.cartridge.type" ! U1 getvar "ribbon.cartridge.length" ! U1 getvar "ribbon.cartridge.inserted" ribbon.ribbon_low.warning : 50 , Choices: off,5,10,15,25,50,75,100 ! U1 getvar "ribbon" ! U1 getvar "ribbon.ribbon_low.warning" ! U1 setvar "ribbon.ribbon_low.warning" "75" ! U1 setvar "ribbon.ribbon_low.warning" "off"
Detaljnije informacije o SGD naredbama te posebice o SGD naredbama za vrpcu (
“ribbon”
) potražite u Vodiču za ZPL programere.
Za slanje naredbi i primanje statusa od pisača može se upotrijebiti Zebra Setup Utilities putem značajke
Open Communication With Printer
(Otvori komunikaciju s pisačem). Ako želite samo poslati datoteku, upotrijebite
Send a File
(Pošalji datoteku).