1-Slot Charge Only Cradle Troubleshooting

1-Slot Charge Only Cradle Troubleshooting

The following table provides troubleshooting information for the cradle.
Troubleshooting the 1-Slot Charge Only Cradle
Symptom
Possible Cause
Action
The device battery is not charging.
The device was removed from the cradle, or the cradle was unplugged from AC power too soon.
Ensure the cradle is receiving power. Ensure the device is seated correctly. Confirm main battery is charging. The standard battery charges from fully depleted to 80% in less than 1 hour and 20 minutes. The extended battery charges from fully depleted to 80% in less than 1 hour and 50 minutes.
The battery is faulty.
Verify that other batteries charge properly. If so, replace the faulty battery.
The device is not fully seated in the cradle.
Remove and re-insert the device into the cradle, ensuring it is firmly seated.
Extreme battery temperature.
The battery does not charge if the ambient temperature is below 5°C (41°F) or above 40°C (104°F).