4-Slot Battery Charger Troubleshooting

4-Slot Battery Charger Troubleshooting

The following table provides troubleshooting information for the 4-Slot Battery Charger.
Troubleshooting the 4-Slot Battery Charger
Problem
Cause
Solution
The spare Battery Charging LED does not light when the spare battery is inserted.
The spare battery is not correctly seated.
Remove and re-insert the spare battery into the charging slot, ensuring it is correctly seated.
The spare battery not charging.
The charger is not receiving power.
Ensure the power cable is connected securely to the charger and AC power.
The spare battery is not correctly seated.
Remove and re-insert the battery into the battery adapter, ensuring it is correctly seated.
The battery adapter is not seated properly.
Remove and re-insert the battery adapter into the charger, ensuring it is correctly seated.
The battery was removed from the charger, or the charger was unplugged from AC power too soon.
Ensure the charger is receiving power. Ensure the spare battery is seated correctly. The standard and extended battery charges from fully depleted to 90% in less than 4 hours.
The battery is faulty.
Verify that other batteries charge properly. If so, replace the faulty battery.
The ambient temperature of the cradle is too warm.
Move the cradle to an area where the ambient temperature is between 5°C (41°F) and 40°C (104°F).