Heater Control
Heater Control
Heater Control
The device heater ensures optimum performance in freezers.
The Heater Control app is only applicable to freezer configurations.
The heater benefits include:
Touch screen heater clears condensation on the display.
Port heater prevents condensation on contacts.
UPS Battery requires a heater to operate below freezing temperatures.
The user interface displays current temperatures.
Temperatures
The Status tab displays the current temperature for the following:
Serial Ports
USB Ports
Battery
Keyboard
Touch Panel (Freezer configurations only)
Ambient.
Serial Port Heater
Use the Serial Ports Heater tab to enable and set the heater for the serial ports.
Enable Heater
- Turns on or off the serial port heater. When on, the switch turns red.
Heater on threshold
- Set the temperature at which the heater turns on (default - 5°C/41°F).
Heater off threshold
- Set the temperature at which the heater turns off (default - 15°C/59°F).
USB Port Heater
Use the USB Ports Heater tab to enable and set the heater for the USB ports.
Enable Heater
- Turns on or off the USB port heater. When on, the switch turns red.
Heater on threshold
- Set the temperature at which the heater turns on (default - 5°C/41°F).
Heater off threshold
- Set the temperature at which the heater turns off (default - 15°C/59°F).
Battery Heater
Use the Battery Heater tab to enable and set the heater for the battery.
Enable Heater
- Turns on or off the battery heater. When on, the switch turns red.
Heater on threshold
- Set the temperature at which the heater turns on (default - 15°C/59°F).
Heater off threshold
- Set the temperature at which the heater turns off (default - 20°C/68°F).
Touch Panel Heater
Touch Panel Heater tab is available on Freezer configurations only.
Use the Touch Panel Heater tab to enable and set the heater for the touch panel.
Enable Heater
- Turns on or off the Touch panel heater. When on, the switch turns red.
Heater on threshold
- Set the temperature at which the heater turns on (default - 15°C/59°F).
Heater off threshold
- Set the temperature at which the heater turns off (default - 22°C/72°F).
Keyboard Heater
Use the Keyboard Heater tab to enable and set the heater for the keyboard.
Enable Heater
- Turns on or off the keyboard heater. When on, the switch turns red.
Heater on threshold
- Set the temperature at which the heater turns on (default - 15°C/59°F).
Heater off threshold
- Set the temperature at which the heater turns off (default - 22°C/72°F).