Setting the Power Failure Recovery Mode Jumper

Setting the Power Failure Recovery Mode Jumper

If a Printer Connectivity module is installed in your printer. the printer can be configured to restart itself after a power failure.
The Printer Connectivity module have a Power Failure Recovery jumper set to OFF. With the jumper set to ON, the printer will automatically power itself ON when plugged into an active AC power source.
The discharge of electrostatic energy that accumulates on the surface of the human body or other surfaces can damage or destroy the printhead or electronic components used in this device. You must observe static-safe procedures when working with the printhead or the electronic components.
  1. Disconnect the DC power plug and any interface connectors from the back of the printer.
  2. Remove the module access door and connectivity module. See Removing the Printer Connectivity Modules.
  3. Move the AUTO (Power Failure Recovery Mode) jumper from the OFF position to the ON position.
  4. Reinstall the connectivity module and module access door. See Installing the Internal Ethernet (LAN) Module or Installing the Serial Port Module.
  5. Reconnect the DC power plug and interface cables to the printer.
Power failure recovery mode is enabled.