Charging the Device
Charging the Device

Charging the Device

To achieve optimal charging results, use only Zebra charging accessories and batteries. Charge batteries at room temperature with the device in sleep mode.
A standard battery charges from fully depleted to 90% in approximately 2 hours and from fully depleted to 100% in approximately 3 hours. In many cases, a 90% charge provides enough charge for daily use. Depending on the usage profile, a full 100% charge may last for approximately 14 hours of use.
The device or accessory always performs battery charging in a safe and intelligent manner and indicates when charging is disabled due to abnormal temperatures via its LED, and a notification appears on the device display.
Temperature
Battery Charging Behavior
20 to 45°C (68 to 113°F)
Optimal charging range.
0 to 20°C (32 to 68°F) / 45 to 50°C (113 to 122°F)
Charging slows to optimize the JEITA requirements of the cell.
Below 0°C (32°F) / Above 50°C (122°F)
Charging stops.
Above 55°C (131°F)
The device shuts down.
To charge the main battery:
  1. Connect the charging accessory to the appropriate power source.
  2. Insert the device into a cradle or attach to a power cable (minimum 9 volts / 2 amps).
    The device turns on and begins charging. The Charging/Notification LED blinks amber while charging, then turns solid green when fully charged.