Battery Charging
Battery Charging
View content for :
Product:

Battery Charging

The
RS6100
charging LED indicates scanner battery charging status
, and the spare battery charger LED indicates spare battery charging status
.
New batteries from the factory arrive in Ship Mode for protection. Insert them into a charger (cradle or battery charger) to activate the battery.
Charging LED Indicators
State
Indication
Off
The battery is not charging.
The
RS6100
or battery is not inserted correctly in the cradle or charger or is not connected to a power source.
Cradle is not powered.
Solid Amber
Battery is charging.
Solid Green
Battery charging is complete.
Fast Blinking Red
(2 blinks/second)
Charging error, such as:
  • Battery temperature is too low or too high for charging.
  • The battery has reached the charge cycle time-out period. Battery charging has gone on too long without completing a full charge cycle (typically eight hours).
Solid Red
Unhealthy battery is charging or fully charged.
Charge batteries in temperatures from 5°C to 40°C (41°F to 105°F). The standard battery charges from 0% to 90% in less than two and a half hours at room temperature. When the charging temperature is between 5°C to 10°C (41°F to 50°F), the standard battery charges in less than five hours.
The device and charger monitor battery temperature. Battery charging is only performed when the battery is within safe charging temperature limits. At higher temperatures (at approximately +35 °C (+95 °F) the device or charger may, for small periods of time, alternately enable and disable battery charging to keep the battery at acceptable temperatures. This process may increase charging time. The
RS6100