Performing Manual Sensor Calibration
Performing Manual Sensor Calibration

Performing Manual Sensor Calibration

You may need to manually calibrate the printer if you see issues with the print output.
  1. Touch
    Print
    Sensors
    Manual Calibration
    .
    Manual Calibration option showing Start Calibration button
  2. Touch
    Start Calibration
    .
  3. Follow the steps in the calibration procedure as prompted.
    When performing manual calibration with a linerless cutter, remove any media that extends out of the cutter. Leaving any media sticking out can block the label taken sensor (1), so calibration will fail.
    Linerless cutter label taken sensor location
    Follow the calibration procedure exactly as presented.
    • Touch
      Next
       to advance to the next prompt.
    • You may press and hold
      CANCEL
      on the control panel at any step in the procedure to cancel the calibration process.
  4. When calibration is complete, press
    PAUSE
    to exit pause mode and enable printing.