Parameter | ICL | Fujitsu | Wincor-Nixdorf Mode A | Wincor-Nixdorf Mode B/ OPOS/JPOS |
---|---|---|---|---|
Baud Rate | 9600 | 9600 | 9600 | 9600 |
Parity | Even | None | Odd | Odd |
Stop Bits | One | One | One | One |
Data Bits | 8-bit | 8-bit | 8-bit | 8-bit |
Hardware Handshaking | RTS/CTS Option 3 | None | RTS/CTS Option 3 | RTS/CTS Option 3 |
Software Handshaking | None | None | None | None |
Serial Response Timeout | 9.9 Seconds | 2 Seconds | None | None |
RTS Line State | High | Low | Low | Low = No data to send |
Beep On <BEL> | Disable | Disable | Disable | Disable |
Transmit Code ID | Yes | Yes | Yes | Yes |
Data Transmission Format | Data/Suffix | Data/Suffix | Data/Suffix | Data/Suffix |
Prefix | None | None | None | None |
Suffix | CR (1013) | CR (1013) | CR (1013) | CR (1013) |
In the Wincor-Nixdorf Mode A/B, when CTS is low, scanning is disabled and when CTS is high, scanning is enabled. If you scan Wincor-Nixdorf RS-232 Mode A/B without connecting the scanner to the proper host, it may appear unable to scan. In this case, scan a different RS-232 host type within 5 seconds of cycling power to the scanner. |
Parameter | Olivetti | Omron | CUTE | NCR | Datalogic |
---|---|---|---|---|---|
Baud Rate | 9600 | 9600 | 9600 | 9600 | 9600 |
Parity | Even | None | Even | Odd | Odd |
Stop Bits | One | One | One | One | One |
Data Bits | 7-bit | 8-bit | 7-bit | 7-bit | 7-bit |
Hardware Handshaking | None | None | None | None | None |
Software Handshaking | ACK/NAK | None | None | None | None |
Serial Response Timeout | 9.9 Seconds | 9.9 Seconds | 9.9 Seconds | 9.9 Seconds | 9.9 Seconds |
RTS Line State | Low | High | High | High | High |
Beep On <BEL> | Disable | Disable | Disable | Disable | Enable |
Transmit Code ID | Yes | Yes | Yes | Yes | Yes |
Data Transmission Format | Prefix/Data/ Suffix | Data/Suffix | Prefix/Data/ Suffix | Prefix/Suffix* | Data/Suffix |
Prefix | STX (1003) | None | STX (1002) | STX * | None |
Suffix | ETX (1002) | CR (1013) | CR (1013) ETX (1003) | ETX * | CR (1013) |
The CUTE host disables all parameter scanning, including Set Defaults. If you inadvertently select CUTE, scan Enable Parameter Barcode Scanning, and then change the host selection. |