Parameter #
1118
(SSI # F8h 04h 5Eh)
When this parameter is enabled, the scanner can send unsolicited heartbeat messages to assist in diagnostics. The range is 0 - 9999.
The heartbeat event is sent as decode data (with no decode beep) in the form of:
MOTEVTHB:nnn
Where:
nnn
is a three-digit sequence number starting at 001 and wrapping after 100.
To enable this parameter and set the desired unsolicited heartbeat interval, scan one of the following time interval barcodes, or scan Set Another Interval followed by four barcodes from Numeric Barcodes that correspond to the desired number of seconds.
Scan Disable Unsolicited Heartbeat Interval to turn off the feature.
10 Seconds (10)
1 Minute (60)
Set Another Interval
*Disable Unsolicited Heartbeat Interval (0)