5-Slot Charge Only Cradle Troubleshooting
5-Slot Charge Only Cradle Troubleshooting

5-Slot Charge Only Cradle Troubleshooting

The table below provides troubleshooting options for the cradle.
Troubleshooting the 5-Slot Charge Only Cradle
Problem
Cause
Solution
The battery is not charging.
The device was removed from the cradle too soon.
Replace the device in the cradle. The battery charges from fully depleted to 90% in less than 2 hours and from fully depleted to 100% in approximately 3 hours.
The battery is faulty.
Verify that other batteries charge properly. If so, replace the faulty battery.
The device is not inserted correctly in the cradle.
Remove the device and reinsert it correctly. Verify charging is active. Touch
Settings
>
Battery
to view battery status.
The ambient temperature of the cradle is too warm.
Move the cradle to an area where the ambient temperature is between 5°C (+41°F) and +40°C (+104°F).