Item | CS-RAC | |||||||
---|---|---|---|---|---|---|---|---|
Destination | Europe | North America | Europe | North America | Europe | North America | ||
Power Protection Unit | Yes | No | N/A | Yes | No | N/A | No | N/A |
Part Code | CS-RAC- 30-E-01 | CS-RAC- 30-E-00 | CS-RAC- 30-N-00 | CS-RAC- 60-E-01 | CS-RAC- 60-E-00 | CS-RAC- 60-N-00 | CS-RAC- 30-EN-02 | CS-RAC- 60-N-02 |
Maximum Device Capacity | 30 Devices | 60 Devices | 30 Devices | |||||
Dimensions H x W x D (mm) | 2000 x 550 x 600 | 1960 x 545 x 235 | ||||||
Weight (kg) | 68 kg | 67 kg | 67 kg | 87 kg | 86 kg | 86 kg | 35 kg | 35 kg |
Maximum Loading Per Shelf | 20 kg Evenly Distributed | |||||||
Input Voltage | 220 - 240 V | 100 - 120 V | 220 - 240 V | 100 - 120 V | 220 - 240 V | 100 - 120 V | ||
Power Distribution | Maximum of 1 Ampere Per Output Socket; Total Current Not to Exceed 7.5 A/ 13 A/ 10 A | |||||||
Maximum Current | 7.5 A | 13 A | 16 A | 7.5 A | 13 A | 16 A | 13 A | 16 A |
Operating Temp Range (°C) | 0°C to 30°C | |||||||
Maximum Humidity | 80% None Condensing | |||||||
Maximum Altitude | < = 2000 Meters |