Technical Specifications

Technical Specifications

The following table details technical specifications for the Rack.
Item
CS-RAC
Destination
Europe
North America
Europe
North America
Power Protection Unit
Yes
No
N/A
Yes
No
N/A
Part Code
CS-RAC- 30-E-1
CS-RAC- 30-E-0
CS-RAC- 30-N-0
CS-RAC- 60-E-1
CS-RAC- 60-E-0
CS-RAC- 60-N-0
Maximum Device Capacity
30 Devices
60 Devices
Dimensions H x W x D (mm)
2000 x 550 x 600
Weight (kg)
68 kg
67 kg
67 kg
87 kg
86 kg
86 kg
Maximum Loading Per Shelf
10 kg Evenly Distributed
Input Voltage
220 - 240 V
220 - 240 V
100 - 120 V
220 - 240 V
220 - 240 V
100 - 120 V
Power Distribution
Maximum of 1 Ampere Per Output Socket; Total Current Not to Exceed 7.5 A/ 13 A/ 10 A
Maximum Current
7.5 A
13 A
10 A
7.5 A
13 A
10 A
Operating Temp Range (°C)
0°C to 30°C
Maximum Humidity
80% None Condensing
Maximum Operating Altitude
< = 2000 Meters