Pin Out Diagrams

Pin Out Diagrams

The following diagrams provide pin-out information for the Power and IO Y cable for FS80 Fixed Industrial Scanners.

Power and IO Y Cable (FS80)

Power and IO Y Cable Pin Out Diagram FS80
Flying Leads Color (24 AWG)
Function
12-Pin A-Coded Male M12 to FS80
8-Pin A-Coded Female M12 to ZIML
Green
Green must be connected to -VDC to operate the Zebra Integrated Multifunction Light.
OUT_COMMON
1
Green
6
Green
Brown
N/A
2
Brown
-
Yellow
OUT2
3
Yellow
-
Red
+VDC
4
Red
1
Red
Grey
IN3
5
Grey
-
White/Violet
IN_COMMON
6
White/Violet
-
Violet
IN5
7
Violet
-
White/Yellow
IN6
8
White/Yellow
-
White/Brown
IN4
9
White/Brown
-
Black
-VDC
11
Black
8
Black
Orange
PASS
-
-
7
White/Orange
Blue
FAIL
-
-
2
White/Blue
White/Green
RESERVED_PROG
-
3
White/Green

Power and IO Y Cable (FS42)

Power and IO Y Cable Pin Out Diagram (FS42)
Flying Leads Color (24 AWG)
Function
12-Pin A-Coded Male M12 to FS42
8-Pin A-Coded Female M12 to ZIML
Yellow
GPIO2
1
Yellow
-
-
White/Yellow
TXD
2
White/Yellow
-
-
Brown
RXD
3
Brown
-
-
-
GPIO4
4
Orange
4
Orange
-
GPIO5
5
Blue
5
Blue
White/Violet
COMMON_IN
6
White/Violet
-
-
Red
DC_IN
7
Red
1
Red
Black
GND
8
Black
8
Black
Green
COMMON_OUT
9
Green
6
Green
White/Brown
GPIO0
10
White/Brown
-
-
Violet
GPIO1
11
Violet
-
-
Grey
GPIO3
12
Grey
-
-
Orange
PASS_OUT
-
-
7
White/Orange
Blue
FAIL_OUT
-
-
2
White/Blue
White/Green
RESERVED_PROG
-
-
3
White/Green

8-Pin A-Coded Male Input Connector on Zebra Integrated Multifunction Light

8-Pin A-Coded Male Input Connector Pin Out Diagram
Pin
Signal
Description
1
VDC+
The positive power terminal (24V relative to VDC-)
2
FAIL_OUT
The pulse output from the light that is triggered when a FAIL command is sent on CONFIG_IN (+24V relative to COMMON_OUT).
3
RESERVED_PROG
This is reserved for use with a Zebra ZIML firmware update tool (connect to VDC- or leave unconnected).
4
STROBE_IN
The strobe pulse input to the light (+24V relative to COMMON_OUT).
5
CONFIG_IN
The command/configuration pulse input to the light (+24V relative to COMMON_OUT)
6
COMMON_OUT
The low side reference for the light's output signals.
7
PASS_OUT
The pulse output from the light that is triggered when a PASS command is sent on CONFIG_IN (+24V relative to COMMON_OUT)
8
VDC-
Negative power terminal.