Zebra Rapixo CoF has 8 16-bit timers, which operate based on a specified clock source. Timer output signals allow you to control the exposure time and other external events related to the video source (such as a strobe). A timer output signal can be output on any of the auxiliary output signals or auxiliary I/O signals in output mode. A timer output can also be sent to a video source via the CoaXPress trigger output signal.
The timers can use one of the following as a clock source:
A 125MHz internal clock source.
A clock based on the output of another timer set in continuous mode.
To route a timer output on an auxiliary signal, use the Aurora Imaging Library-Lite function MdigControl() with M_IO_SOURCE + M_AUX_IOn set to M_TIMERn. To set up a timer, use MdigControl() with M_TIMER_....