Trigger Sequence Mode
Trigger Sequence Mode

Trigger Sequence Mode

Trigger Sequence Mode enables a user-defined Sequencer Trigger pattern.
The operation of this mode is controlled using the following commands:
  • SequencerSetActive
    - confirm the index number displayed on the next trigger reception.
  • SequencerSetStart
    - configure the index number to execute at the start of the
    TriggerSequencer
    mode.
  • SequencerReset
    - enable this to switch the index number executed to the one specified in
    SequencerSetStart
    during
    TriggerSequencer
    mode operation.
  • SequencerRepetition
    - this parameter applies to
    TriggerSequencer
    patterns with the
    SequencerROINextIndex
    set to
    0 (Off)
    . When execution completes, the index
    SequencerROINextIndex
    is set to
    0 (Off)
    , and the
    SequencerRepetition
    (range = 1-255) is decremented internally. If the result of the decrement is not zero, the
    TriggerSequencer
    pattern restarts from the index specified in
    SequencerSetStart
    . If the result of the decrement is zero, the status updates to
    Acquisition Stop
    and external triggers are not accepted.