Lookup Table

Lookup Table

The Lookup Table (LUT) function generates a non-linear mapping between signal values captured on the sensor and those output from the camera.
Specify the output curve using 257 setting points (indexes).
Configure the settings in the following table to use the Lookup Table function.
Item
Setting Value/Selectable Range
Description
LUTMode
LUT
Use LUT.
LUTSelector
Red, Green, Blue
Select the LUT channel to control.
LUTIndex
0-256
Select the LUT index to configure. Indexes represent the possible pixel values captured on the sensor, from the lowest value (Index 0) to the highest (Index 256). For example, Index 0 represents a full black pixel, and Index 256 represents a full white pixel.
LUTValue
0-4095
Set the LUT output value for the selected index.
LUT values range from 0 to 4095. Linear interpolation is used to calculate LUT values between the index points.
Values between points are determined using the linear interpolation values of data to the left and right.