Sequencer

Sequencer

Use the Sequencer function to define up to 32 index combinations of exposure time, gain, ROI, and other settings enabled each time a trigger is received. This is helpful for use cases that require capturing multiple exposures of objects under inspection to adjust for areas or components with significantly different reflectance levels. Specify the following index in the sequence and the order in which indexes execute. Multiple indexes can be implemented repeatedly.
Two operation modes (
TriggerSequencer
mode and
CommandSequencer
mode) are available for the Sequencer function.
If the values of
ImageFormatControl
width and height are smaller than
SequencerControl,
SequencerWidth,
and
SequencerHeight,
the image may not be output as expected. When using
SequencerWidth
or
SequencerHeight,
set the width and height to the default values in advance.