CV60-AS02MC Timing Diagram

CV60-AS02MC Timing Diagram

The following diagram outlines triggering behavior when
ExposureMode
is set to
TriggerTimed
and the
FrameStart
trigger is
On
.
PixelFormat
Frame Period [A] (usec)
Time Between Trigger Start and Exposure Start [B] usec
Binning Off
Mono8
20,080
32.8
Mono10/Mono12
40,161
62.5
Mono10Packed/Mono12Packed
30,121
62.5
Bayer8
20,080
32.8
Bayer10/Bayer12
40,161
62.5
Bayer10Packed/Bayer12Packed
30,121
62.5
Horizontal Binning On
Mono8
13,038
32.8
Mono10
25,189
62.5
Mono10Packed
25,189
62.5
Vertical Binning On
Mono8
13,038
32.8
Mono10
25,189
62.5
Mono10Packed
25,189
62.5
Horizontal and Vertical Binning On
Mono8
5,015
19
Mono10
10,030
31.8
Mono10Packed
7,519
31.8
The following diagram outlines triggering behavior when
ExposureMode
is set to
TriggerWidth
and the
FrameStart
trigger is
Enabled
.
PixelFormat
FramePeriod [A] (usec)
Time Between Trigger Start and Exposure Start [B] usec
Time Between Trigger End and Exposure End [C] usec
Time From Exposure End to Next Trigger [D] usec
Binning Off
Mono8
17,857
35.2
35.2
35.3
Mono10/Mono12
34,247
66.5
66.5
66.7
Mono10Packed/Mono12Packed
34,247
66.5
66.5
66.7
Bayer8
17,857
35.2
35.2
35.3
Bayer10/Bayer12
34,247
66.5
66.5
66.7
Bayer10Packed/Bayer12Packed
34,247
66.5
66.5
66.7
Horizontal Binning On
Mono8
17,857
35.2
35.2
35.4
Mono10
34,247
66.5
66.5
66.7
Mono10Packed
34,247
66.5
66.5
66.7
Vertical Binning On
Mono8
17,857
35.2
35.2
35.3
Mono10
34,247
66.5
66.5
66.8
Mono10Packed
34,247
66.5
66.5
66.8
Horizontal and Vertical Binning On
Mono8
17,857
35.2
35.2
35.3
Mono10
34,247
66.5
66.5
66.7
Mono10Packed
34,247
66.5
66.5
66.8