CV60-AS12MC Timing Diagrams
CV60-AS12MC Timing Diagrams

CV60-AS12MC Timing Diagrams

The following diagram outlines triggering behavior when
ExposureMode
is set to
TriggerTimed
and
FrameStart
trigger is
On
.
PixelFormat
Frame Period [A] (usec)
Time Between Trigger Start and Exposure Start [B] usec
Binning Off
Mono8
107,528
66.1
Mono10/Mono12
217,393
132
Mono10Packed/Mono12Packed
161,291
132
Bayer8
107,528
66.1
Bayer10/Bayer12
217,393
132
Bayer10Packed/Bayer12Packed
161,291
132
Horizontal Binning On
Mono8
66,226
66.3
Mono10
133,334
132.1
Mono10Packed
133,334
132.1
Vertical Binning On
Mono8
66,226
66.3
Mono10
133,334
132.1
Mono10Packed
133,334
132.1
Horizontal and Vertical Binning On
Mono8
66,226
66.3
Mono10
133,334
132.1
Mono10Packed
133,334
132.1
The following diagram outlines triggering behavior when
ExposureMode
is set to
TriggerWidth
and the
FrameStart
trigger is
On
.
PixelFormat
FramePeriod [A] (usec)
Time Between Trigger Start and Exposure Start [B] usec
Time Between Trigger End and Exposure End [C] usec
Time From Exposure End to Next Trigger [D] usec
Binning Off
Mono8
66,226
66.2
66.2
240.6
Mono10/Mono12
133,334
132.1
132.1
482.8
Mono10Packed/Mono12Packed
133,334
132.1
132.1
482.8
Bayer8
66,226
66.2
66.2
240.6
Bayer10/Bayer12
133,334
132.1
132.1
482.8
Bayer10Packed/Bayer12Packed
133,334
132.1
132.1
482.8
Horizontal Binning On
Mono8
66,226
66.3
66.3
240.6
Mono10
133,334
132.1
132.1
482.8
Mono10Packed
133,334
132.1
132.1
482.8
Vertical Binning On
Mono8
66,226
66.2
66.2
240.6
Mono10
133,334
132.1
132.1
482.8
Mono10Packed
133,334
132.1
132.1
482.8
Horizontal and Vertical Binning On
Mono8
66,226
66.2
66.2
240.6
Mono10
133,334
132.1
132.1
482.8
Mono10Packed
133,334
132.1
132.1
482.8