To power your unit, you can either use an AC or DC power supply, depending on the Zebra 4Sight XV7.
Powering Using AC Power Supply
To power a Zebra 4Sight XV7 unit that comes with an installed AC power supply, connect the female end of the power cable to the AC power connector found on the back of your Zebra 4Sight XV7 unit and connect the male end of the power cable to your AC source. The AC power connector port on the back of your unit is shown below:
When connecting your Zebra 4SightXV7 to AC power, ensure that you are connecting your power cable to a power source that provides an earthing connection.
Powering Using DC Power Supply
To power a Zebra 4Sight XV7 unit that comes with an installed DC power supply, connect one cable to each of the 0V, 24V, and ground connectors found on the back of your Zebra 4Sight XV7 unit.
Each cable will need a crimped ring terminal on the end that connects to the back of the Zebra 4Sight XV7 unit. Once the ring terminals are secured to the cables, slide the cable terminals onto the 24 V and 0 V connectors, and use a Philipps screwdriver to tighten the cables to the power supply connectors. The last connector is the ground connector and the cable terminal must be secured with a nut instead of a Philips screw.
When connecting your Zebra 4Sight XV7 to DC power, ensure that the selected power supply, wire gauge, and length of cable meet the requirement of your setup. You must also account for any voltage drop that might occur when connecting your power supply. The power supply equipment shall be supplied by an Approved/Listed/Certified vendor and be isolated from the Mains by Reinforced Insulation. For information on the requirements to run the XV7 power supply, see the Electrical Specifications section.
Once the DC power cables are secured to the 4Sight XV7 power connector at the back of the unit, connect the other ends of the cables to the DC power source that you are using.
The DC source shall have a 40A all-pole circuit breaker available at the building DC power source.
To turn off the Zebra 4Sight XV7 unit, flip the power switch to off. You can also shut down the unit by shutting down Windows with the Shut Down command.
Rebooting the Unit
When the unit is on, you can reboot the unit by pressing the Control+Alt+Delete on your keyboard simultaneously, or you can select the
Restart
option from the Windows Start menu.
If you need to enter the UEFI Setup utility, you must press Esc during power-on self-test (POST). You only have a few moments to press the F12 key before the boot-up process continues.
On legacy computers, the UEFI was referred to as a BIOS. In some menu items, BIOS and UEFI are still used interchangeably.