Performing a Factory Reset Using ADB

Performing a Factory Reset Using ADB

Initiate a Factory Reset on the ET40/ET45 using ADB.
Go to the Zebra Support & Downloads website at zebra.com/support and download the appropriate Factory Reset file to a host computer.
  1. Connect the device to a host computer using a USB-C cable.
    When transferring files or debugging, ensure only one USB connection to the device exists. For example, do not dock the device or attach an expansion back if using a USB cable.
  2. Go to
    Settings
    .
  3. On A11, touch
    System
    Advanced
    Developer options
    .
  4. On A13, touch
    System
    Developer options
    .
  5. Slide the
    USB debugging
    switch to the
    ON
    position.
  6. If the device and host computer are connected for the first time, the
    Allow USB debugging?
    dialog box with the
    Always allow from this computer
    check box displays. Select the check box, if required.
  7. Touch
    OK
    .
  8. On the host computer, navigate to the
    platform-tools
    folder and open a command prompt window.
  9. Type
    adb devices
    .
    The following displays:
    List of devices attached XXXXXXXXXXXXXXX device
    Where XXXXXXXXXXXXXXX is the device number.
    If the device number does not appear, ensure that the ADB drivers are installed properly.
  10. Type:
    adb reboot recovery
  11. Press
    Enter
    .
    The System Recovery screen appears on the device.
  12. Press
    Volume Up
    and
    Volume Down
    buttons to navigate to
    Apply upgrade from ADB
    .
  13. Press
    Power
    .
  14. On the host computer command prompt window type
    adb sideload <file>
    .
    where: <file> = the path and filename of the zip file.
  15. Press
    Enter
    .
    The Factory Reset package installs, and then the System Recovery screen appears on the device.
  16. Press