Cradle Troubleshooting
Cradle Troubleshooting

Cradle Troubleshooting

Provides solutions to common cradle issues
Cradle Troubleshooting
Symptom
Possible Cause
Action
Device battery is not charging.
Device was removed from cradle or cradle was unplugged from AC power too soon.
Ensure cradle is receiving power. Ensure device is seated correctly. Confirm main battery is charging. The battery fully charges in approximately four hours.
Battery is faulty.
Verify that other batteries charge properly. If so, replace the faulty battery.
The device is not fully seated in the cradle.
Remove and re-insert the device into the cradle, ensuring it is firmly seated.
Extreme battery temperature.
Battery does not charge if ambient temperature is below 0°C (32°F) or above 40°C (104°F).
When the device is placed in the cradle, the cradle LED does not blink.
Cradle is not powered.
Ensure cradle is receiving power.
Cradle firmware is corrupted.
Contact system administrator.
The device is not operational.
Contact system administrator.
Communication error between the cradle and device.
Contact system administrator.
Cradle LED blinks red.
The cradle is issued an unlock command and it fails to unlock.
Contact system administrator.
Cradle is overheating due to continuous lock/unlock or other cradle faults.
Contact system administrator.