Performing Auto Calibration
Performing Auto Calibration

Performing Auto Calibration

You can set the printer to perform an auto calibration (CALIBRATE) or a short calibration (SHORT CAL) using the POWER UP ACTION or HEAD CLOSE ACTION parameters.
  • CALIBRATE—Adjusts sensor levels and thresholds, determines the label length, and feeds the media to the next web.
  • SHORT CAL—Sets the media and web thresholds without adjusting sensor gain, determines the label length, and feeds the media to the next web.
See Power-Up Action or Head-Close Action in System Menu for details.