Flying Leads Color (24 AWG) | Function |
---|---|
Green
Green must be connected to -VDC to operate the Zebra Integrated Multifunction Light. | OUT_COMMON |
Brown | Not in Use |
Yellow | OUT2 |
Red | +VDC |
Grey | IN3 |
White/Violet | IN_COMMON |
Violet | IN5 |
White/Yellow | IN6 |
White/Brown | IN4 |
Black | -VDC |
Orange | PASS_OUT |
Blue | FAIL_OUT |
White/Green | RESERVED_PROG |
Pin | Signal | Description |
---|---|---|
1 | VDC+ | The positive power terminal (24V relative to VDC-) |
2 | FAIL_OUT_NPN | The pulse output from the light that is triggered when a FAIL command is sent on CONFIG_IN (+24V relative to OUTPUT-) |
3 | INPUT- (COMMON_IN) | The low side reference for the input signals to the light. |
4 | STROBE_IN_NPN | The strobe pulse input to the light (+24V relative to INPUT-) |
5 | CONFIG_IN | The command/configuration pulse input to the light (+24V relative to INPUT-) |
6 | OUTPUT- (COMMON_OUT) | The low side reference for the light's output signals. The user provides the voltage of OUTPUT-. |
7 | PASS_OUT_NPN | Pass the output from the light that is triggered when a PASS command is sent on CONFIG_IN (+24V relative to OUTPUT-). |
8 | VDC- | Negative power terminal. |