Illumination Operation

Illumination Operation

The light supports Deca OverDrive and Standard OverDrive modes based on the duration of the strobe pulse.
When using the light, the start time of sensor exposure and the light strobing match within 1 μs. The output strobe duration is adjustable in steps of 1 μs. Deca and Standard OverDrive Modes are implemented depending on the duration of the strobe pulse.
The light also supports Hidden Strobe mode, which strobes the light at a high frequency that is not visible to humans, making the light appear constantly powered on. Hidden Strobe supports exposures up to 200μsec. Exposures greater than 200μsec may cause the strobing to become visible.