Problem | Cause | Solution |
---|---|---|
During communication, no data transmits, or transmitted data was incomplete. | Device removed from cradle during communications. | Replace device in cradle and retransmit. |
Incorrect cable configuration. | Ensure that the correct cable configuration. | |
Device has no active connection. | An icon is visible in the status bar if a connection is currently active. | |
Battery is not charging. | Device removed from the cradle too soon. | Replace the device in the cradle. The battery charges from fully depleted to 90% in approximately 2.5 hours and from fully depleted to 100% in approximately three hours. |
Battery is faulty. | Verify that other batteries charge properly. If so, replace the faulty battery. | |
Device is not inserted correctly in the cradle. | Remove the device and reinsert it correctly. Verify charging is active. Touch Settings > System > About phone > Status to view battery status. | |
Ambient temperature of the cradle is too warm. | Move the cradle to an area where the ambient temperature is between 5°C (+41°F) and +40°C (+104°F). |