Problem | Cause | Solution |
---|---|---|
The Spare Battery Charging LED does not light when the spare battery is inserted. | The spare battery is not correctly seated. | Remove and reinsert the spare battery into the charging slot, ensuring it is correctly seated. |
The spare battery is not charging. | The charger is not receiving power. | Ensure the power cable is connected securely to both the charger and to AC power. |
The spare battery is not correctly seated. | Remove and re-insert the battery into the battery adapter, ensuring it is correctly seated. | |
The battery adapter is not seated properly. | Remove and reinsert the battery adapter into the charger, ensuring it is correctly seated. | |
The battery was removed from the charger or the charger was unplugged from AC power too soon. | Ensure that the charger is receiving power. Ensure the spare battery is seated correctly. The battery charges from fully depleted to 90% in less than 2 hours. | |
The battery is faulty. | Verify that other batteries charge properly. If so, replace the faulty battery. | |