Sensor Settings
View content for :
Product:

Sensor Settings

For information about sensor calibration, see Calibrating the Ribbon and Media Sensors.
Sensor Settings
Sensor Setting
Description
Sensor Type
Select the media sensor that is appropriate for the media that you are using. The reflective sensor can be used with all media types. The transmissive sensor should be used only for simple gap media.
Accepted values:
  • TRANSMISSIVE
  • REFLECTIVE
Related ZPL command(s):
^JS
SGD command used:
device.sensor_select
Printer web page:
View and Modify Printer Settings
Media Setup
Label Sensor
Set the sensitivity of the label sensor.
This value is set during sensor calibration. Do not change this setting unless you are told to do so by Zebra Technical Support or by an authorized service technician.
Accepted values:
0 – 255
SGD command used:
ezpl.label_sensor
Printer web page:
View and Modify Printer Settings
Calibration
Take Label
Set the intensity of the take label LED.
This value is set during sensor calibration. Do not change this setting unless you are told to do so by Zebra Technical Support or by an authorized service technician.
Accepted values:
0 – 255
SGD command used:
ezpl.take_label
Printer web page:
View and Modify Printer Settings
Calibration