The range for this parameter is
2-255
with a default value of
66
.
The minimum decode processing time is defined as the time in which the scanner stops decoding when an object is removed or left stationary in the imaging field of view.
The maximum decode processing time is defined as the time in which the scanner stops decoding when an object is left in or is moving in the field of view.
Both the maximum and minimum times are configured using a single setting. The relationship of this setting is as follows:
X < 25 | 250 ms | 2.5 seconds |
For example, a setting value of 100 results in the scanner turning off approximately 1 second after an object is removed from the field of view or 10 seconds while an object is in the field of view moving.
The default value of the setting is
66
, which results in a minimum time of
660 ms
and a maximum time of
6.6 sec
.
Adjust this setting based on your requirements. For example, when doing PDF prioritization, this parameter should be set to a value where the maximum time is above the PDF prioritization timeout.