RS-232 Device Port Configuration

RS-232 Device Port Configuration

Scan the appropriate RS-232 Device Port Configuration barcodes to select the devices and ports to attach to the MP72.
Ensure the devices connected to the MP72 correctly match the device port configuration option selected. For example, if option 1 is selected, ensure a dual cable scale is connected to the Aux 1 port and an RS-232 scanner is connected to the Aux 2 port. Powering on the MP72 with connected devices that do not match the selected option can result in communication failures.
Available configurations/options are:
  • *0 = Aux 1 Sensormatic, and Aux 2 Scanner
  • 1 = Aux 1 Dual Cable Scale and Aux 2 Scanner
  • 2 = Aux 1 Sensormatic, and Aux 2 Dual Cable Scale
  • 4 = Aux 1 Third Party Scale, Aux 2 Sensormatic
  • 5 = Aux 1 Sensormatic, and Aux 2 Disabled
  • 6 = Aux 1 Dual Cable Scale, and Aux 2 Disabled
  • 7 = Aux 1 Third Party Scale, and Aux 2 Disabled
  • 8 = Aux 1 Disabled, and Aux 2 Scanner
  • 9 = Aux 1 Disabled, and Aux 2 Dual Cable Scale
  • 10= Aux 1 Disabled, and Aux 2 Sensormatic
  • 11= Aux 1 Disabled, and Aux 2 Disabled
After scanning a device port parameter, cycle power to the scanner (disconnect and re-connect the scanner cable) or reset the MP72 (a button combination) to allow the above setting to take effect. Power cycling is not required for 123Scan programming.