Antennas Tab
View content for :
Platform:

Antennas Tab

If the selected RFID reader uses external antennas (for example, Zebra FX9600), the
Antennas
tab is available to configure which antennas are connected to the reader, where they are on the site map, and whether they are enabled (turned on / connected). On the right of some fields, there is a symbol indicating whether the field is still in its device-configured state.
After configuring information about the antenna connected to a specific port, click
Add
.
After configuring the
Antennas
tab, use the
Antenna Defaults
and
Antenna Overrides
tabs, accessible from the
Modes
tab, to control the antennas' power, session, select, and target the RFID reads. These specify how to use the physical antennas (defined on this tab) to do RFID scanning.
Antennas Tab
Screenshot of the Antennas tab.
Antennas Tab Fields
Field
Description
Enabled
Allows you to enable the antenna port.
Location
Specifies the antenna's X, Y, and Z coordinates, relative to the calibrated origin of its reader's site map, in inches.
Cable
Specifies the cable length (in) and loss (dB). The RFID reader uses this information to adjust its power output to compensate for cable attenuation and ensure it can accurately detect tags within the required range.
Specify the length in inches, unlike the units used for specifying it with MotionWorks RFID Reader Manager.
Add
Configures the reader with the antenna information. After you click
Add
, you must specify one or more labels (user-defined key and value pairs) to associate with the antenna to identify it. Click
Add
again to specify an additional label. For example, you could specify the following labels (key-value pairs) if the antenna was reading labels at door 1 and there was low interference.
Screenshot of the possible values you can assign.