Operating Mode Configuration

Operating Mode Configuration

Use Operating Mode to configure a tag's antenna, trigger, communication settings, and applications.
This feature is available for the FXR90 and fixed IoTC readers only.
Fixed Reader Operating Mode
The following settings are available to configure:
  • Mode
    configure tag reporting protocol for different use cases. The options are
    • Simple
      - report all unique read tags.
    • Inventory
      - report all unique read tags in a given time interval, default 1 second.
    • Portal
      - report all unique read tags after the GPI start trigger.
    • Conveyer
      - report all unique read tags for each antenna.
    • Custom
      - report tag reads as defined by the user.
  • Environment
    specify the amount of RFID interference in a given environment.
    • High Interference (Default)
      - operating in the presence of multi or dense readers.
    • Low Interference
      - operating in the presence of another reader, causing interference for a short time.
    • Very High Interface
      - the number of readers in the environment is greater than the number of available channels, or multiple readers operating in close proximity.
    • Auto Detect
      - use the application to access the environment and adjust.
    • Demo
      - demonstrate maximum reader performance in environments where there are no other readers.
  • Tag ID Filter
    - filter tag reporting by ID defined by the user.
    • Operation
      - set the operation for the filter: include, exclude, or disable.
    • Match
      - match tag ID using prefixes, suffixes, or regex.
  • Tag Reporting
    - set tag reporting to continuous, periodic (all antennas), or periodic (per antenna).
  • Cellular Band Filter
    - provide noise cancellation for external non-RFID interference.