Operating Mode Configuration

Operating Mode Configuration

Use Operating Mode to configure a tag's antenna, trigger, communication settings, and applications.
This feature is available for the FXR90 and fixed IoTC readers only.
Fixed Reader Operating Mode
Fixed Reader Operating Mode
The following settings are available to configure:
  • Mode
    configure tag reporting protocol for different use cases. The options are
    • Simple
      - report all unique read tags.
    • Inventory
      - report all unique read tags in a given time interval, default 1 second.
    • Portal
      - report all unique read tags after the GPI start trigger.
    • Conveyer
      - report all unique read tags for each antenna.
    • Custom
      - report tag reads as defined by the user.
  • Environment
    specify the amount of RFID interference in a given environment.
    • High Interference (Default)
      - operating in the presence of multi or dense readers.
    • Low Interference
      - operating in the presence of another reader, causing interference for a short time.
    • Very High Interface
      - the number of readers in the environment is greater than the number of available channels, or multiple readers operating in close proximity.
    • Auto Detect
      - use the application to access the environment and adjust.
    • Demo
      - demonstrate maximum reader performance in environments where there are no other readers.
  • Tag ID Filter
    - filter tag reporting by ID defined by the user.
    • Operation
      - set the operation for the filter: include, exclude, or disable.
    • Match
      - match tag ID using prefixes, suffixes, or regex.
  • Tag Reporting
    - set tag reporting to continuous, periodic (all antennas), or periodic (per antenna).
  • Cellular Band Filter
    - provide noise cancellation for external non-RFID interference.