Trigger Configuration
View content for :
Product:

Trigger Configuration

Configure start and stopping conditions for reading tags and identify tag reporting parameters.
Fixed Reader Trigger Settings
Specify the start condition for a read:
  • When
    Start
    is clicked from the
    Read
    panel.
  • When
    Start
    is clicked, and then the GPI trigger of the device is pressed or released.
  • When
    Start
    is clicked, and the input duration has passed.
  • When the GPI trigger of the handheld device is pressed or released.
Specify a stopping condition for a read:
  • When
    Stop
    is clicked from the
    Read
    panel.
  • After a specified number of total tag reads.
  • After a specified time (ms) has elapsed after tag reading was initiated.
  • After a specified number of inventory rounds. An inventory round consists of reading a tag on each selected antenna port.
  • After the GPI trigger of the device is released.
Configure Report Tag Data to occur after a specified number of tag reads or after each tag is read for a specified number of seconds.
When in Autonomous Mode, reports are sent only when a tag is seen for the first time. This setting is helpful in reducing the tag data network traffic by not reporting duplicated tag data. Configurable settings include:
  • Never - reports no tag data.
  • Immediate - reports data for a new tag immediately.
  • Moderated - reports data for a new tag only after the specified moderation time (ms) and that tag was seen for the moderation duration.
Report tag data and Autonomous Mode are only available for FX7500 fixed readers.