Use the Read feature to manage an inventory. View summary metrics on tag reads by reader or sort, filter, and export tag data to a file. Select the antenna and set the power level to start an inventory.
Data View
Data View
Tag Read Options
Feature
Description
Start an Inventory
Click
Start
to start reading tags.
Highlight Tags
Click the Gear Icon to highlight tags based on the last time seen.
Track Tags
Click
Tag Focus
to enable the tracking of applicable tags such as Monza4, 5, and R6.
Tag Focus prevents read redundancy by suppressing tags that have already been read. This capability prevents multiple reads of the same tags, allowing for more accurate reading of hard-to-read tags.
Export Tag Data
Click
Export
to download the inventory data for offline viewing.
  • Export Summary – download a snapshot of all the tag reads on the Read screen.
  • Export History – download the timeline data for tag reads.
View Tag Details
Click the spreadsheet icon. to view tag details such as Tag ID and User Memory data.
View Performance Data
Click
Charts
to view tag performance data. Use Pie Charts to visualize a distribution of tag reads across enabled devices.
Data View - FXP20
Data View - ET6xW
The following are the Read profile options for ET6xW:
  • Fastest Read
    - This profile prioritizes the rapid reading of tags within a shorter range, maximizing the number of tags processed in minimal time. It is ideal for scenarios where speed is more critical than range.
  • Optimal Battery
    - This profile prioritizes battery longevity, ensuring the device operates efficiently for extended periods. It is ideal for scenarios where battery conservation is crucial.
  • Max Range
    - This profile is designed to read tags from the longest possible distance, focusing on speed and range. It is perfect for applications where detecting tags over a wide area is necessary.
  • Balanced Performance
    - This profile compromises performance and battery life, providing a moderate level of both. It is suitable for general use where neither extreme performance nor maximum battery life is required.
  • Cycle Count
    - This profile focuses on identifying as many unique tags as possible, emphasizing diversity in tag detection. It is used when the goal is to ensure comprehensive tag coverage.
  • User Defined
    - This profile allows customization based on specific user requirements, offering flexibility to meet unique operational needs where predefined profiles do not fit.
The power management features for ET6xW:
  • If the battery is at 6% or below, the device won't connect while charging, ensuring safety and preserving device health.
  • The duty cycle is optimized across all profiles to manage power use efficiently, extending battery life.
  • The device enters sleep mode if no radio operations are executed for 20 seconds, conserving power.