Beeper Volume
View content for :
Platform:

Beeper Volume

Parameter #
140
(SSI # 8Ch)
This parameter selects a beeper volume.
When set to Auto Volume, the scanner will automatically select Medium or High volume based on the detected power input.
  • USB A (500mA) results in a medium volume.
  • USB A (BC1.2) results in a high volume.
  • External 12VDC power source results in High volume.
Selecting High volume while connected to USB A (500mA) will result in the scanner exceeding USB certification power limits.
2d_low_vol
Low Volume (2)
2d_med_vol
Medium Volume (1)
2d_high_vol
High Volume (0)
2d_auto_vol
Auto Volume* (3)
For extra loud environments, set the following barcode to create a louder and more discernible beep. This will set Beeper Volume (140) to High Volume (0) and Scan Tone (145) to Extra High (12).
2d_high_vol_extra_high_tone
High Volume + Extra High Tone