Configuration Setting to Command Cross-reference
Configuration Setting to Command Cross-reference

Configuration Setting to Command Cross-reference

Use the printer's Configuration Report to guide you to make changes to printer behaviors and the associated ZPL or SGD programming commands.
The Printer Configuration Report provides a listing of a majority of the configuration settings that can be set by ZPL or SGD commands. Some sensor values in the middle of the report (1) are used primarily used for service purposes.

ZPL Commands and Configuration Report Callout Cross-Reference

Command
Listing Name
Description
~SD
DARKNESS
Default: 10.0
DARKNESS SWITCH
LOW (Default), MEDIUM, or HIGH
^PR
PRINT SPEED
Default: 152.4 mm/s / 6 IPS (max.) - 203 dpi
101.6 mm/s / 4 IPS (max.) - 300 dpi
~TA
TEAR OFF
Default: +000
^MN
MEDIA TYPE
Default: GAP/NOTCH
SENSOR SELECT
Default: AUTO (
^MNA
- Auto-Detect)
^MT
PRINT METHOD
THERMAL-TRANS or DIRECT-THERMAL
^PW
PRINT WIDTH
Default: 448 (dots for 203 dpi) or 640 (dots for 300 dpi)
^LL
LABEL LENGTH
Default: 1225 (dots) (dynamically updated while printing)
^ML
MAXIMUM LENGTH
Default: 16.5.0IN 419.1MM
USB COMM.
Connection Status: Connected / Not Connected
^SCa
BAUD
Default: 9600
^SC,b
DATA BITS
Default: 8 BITS
^SC,,c
PARITY
Default: NONE
^SC,,,,e
HOST HANDSHAKE
Default: AUTO
^SC,,,,
^SC,,,,,f
PROTOCOL
Default: NONE
— SGD —**
COMMUNICATIONS
Default: NORMAL MODE
SER COMM. MODE
Default: AUTO
^CT
/
~CT
CONTROL CHAR
Default:
<~> 7EH
^CC
/
~CC
COMMAND CHAR
Default:
^> 5EH
^CD
/
~CD
DELIM./CHAR
Default:
<,> 2CH
^SZ
ZPL MODE
Default: ZPL II
— SGD —**
COMMAND OVERRIDE
Default: INACTIVE
^MFa
MEDIA POWER UP
Default: NO MOTION
^MF,b
HEAD CLOSE
Default: FEED
~JS
BACKFEED
Default: DEFAULT
^LT
LABEL TOP
Default: +000
^LS
LEFT POSITION
Default: +0000
~JD
/
~JE
HEXDUMP
Default: NO (
~JE
)
Default: DISABLED
Default: DISABLED
From this point in the Configuration Receipt listing, the printout has sensor settings and values displayed to troubleshoot sensor and media operations. These are typically used by Zebra Tech Support to diagnose printer problems.
** - Not supported with a ZPL command, uses the Set Get Do command in the ZPL manual. See device.command_override.xxxxx in the ZPL Programmer’s manual.
The configuration settings listed here resume after the TAKE LABEL sensor value. These listings contain printer features seldom changed from default or provide status information.
Command
Listing Name
Description
^MP
MODES ENABLED
Default: CWF (See
^MP
Command)
MODES DISABLED
Default: (nothing set)
^JM
RESOLUTION
Default: 448 8/mm (203 dpi); 640 12/mm (300 dpi)
FIRMWARE
Lists ZPL Firmware Version
XML SCHEMA
1.3
HARDWARE ID
Lists Firmware Boot-block Version
LINK-OS VERSION
CONFIGURATION
CUSTOMIZED (after first use)
RAM
2104k........ R:
ONBOARD FLASH
6144k.........E:
^MU
FORMAT CONVERT
NONE
RTC DATE
Date Displayed
RTC TIME
Time Displayed
^JI
/
~JI
ZBI
DISABLED (Requires key to enable)
ZBI VERSION
2.1 (Displayed if installed)
ZBI STATUS
READY
^JH
^MA
~RO
LAST CLEANED
X,XXX IN
HEAD USAGE
X,XXX IN
TOTAL USAGE
X,XXX IN
RESET CNTR2
X,XXX IN
RESET CNTR1
X,XXX IN
NONRESET CNTR0 (1, 2)
X,XXX IN
RESET CNTR1
X,XXX IN
RESET CNTR2
X,XXX IN
SLOT1
EMPTY / SERIAL / WIRED
MASS STORAGE COUNT
0
HID COUNT
0
USB HOST LOCK OUT
OFF /ON
SERIAL NUMBER
XXXXXXXXXXX
^JH
EARLY WARNING
MAINT. OFF
The printer has the ability to set a command or a group of commands once for all receipts (or labels) that follow. Those settings will remain in effect until they are changed by subsequent commands, the printer is reset, or you restore factory defaults.