RS-232 Host-Specific Parameter Settings
RS-232 Host-Specific Parameter Settings

RS-232 Host-Specific Parameter Settings

Some RS-232 hosts use their own parameter default settings.
You can select standard, ICL, Fujitsu, Wincor-Nixdorf Mode A or B, OPOS/JPOS, Olivetti, Omron, Common Use Terminal Equipment (CUTE-LP/LG barcode readers), NCR, or Datalogic and set the appropriate default.
RS-232 Host-Specific Settings
Parameter
ICL
Fujitsu
Wincor-Nixdorf Mode A
Wincor-Nixdorf Mode B/ OPOS/JPOS
Baud Rate
9600
9600
9600
9600
Parity
Even
None
Odd
Odd
Stop Bits
One
One
One
One
Data Bits
8-bit
8-bit
8-bit
8-bit
Hardware Handshaking
RTS/CTS Option 3
None
RTS/CTS Option 3
RTS/CTS Option 3
Software Handshaking
None
None
None
None
Serial Response Timeout
9.9 Seconds
2 Seconds
None
None
RTS Line State
High
Low
Low
Low = No data to send
Beep On <BEL>
Disable
Disable
Disable
Disable
Transmit Code ID
Yes
Yes
Yes
Yes
Data Transmission Format
Data/Suffix
Data/Suffix
Data/Suffix
Data/Suffix
Prefix
None
None
None
None
Suffix
CR (1013)
CR (1013)
CR (1013)
CR (1013)
In the Wincor-Nixdorf Mode A/B, when CTS is low, scanning is disabled and when CTS is high, scanning is enabled. If you scan Wincor-Nixdorf RS-232 Mode A/B without connecting the scanner to the proper host, it may appear unable to scan. In this case, scan a different RS-232 host type within 5 seconds of cycling power to the scanner.
RS-232 Host-Specific Settings
Parameter
Olivetti
Omron
CUTE
Datalogic
Baud Rate
9600
9600
9600
9600
Parity
Even
None
Even
Odd
Stop Bits
One
One
One
One
Data Bits
7-bit
8-bit
7-bit
7-bit
Hardware Handshaking
None
None
None
None
Software Handshaking
ACK/NAK
None
None
None
Serial Response Timeout
9.9 Seconds
9.9 Seconds
9.9 Seconds
9.9 Seconds
RTS Line State
Low
High
High
High
Beep On <BEL>
Disable
Disable
Disable
Enable
Transmit Code ID
Yes
Yes
Yes
Yes
Data Transmission Format
Prefix/Data/ Suffix
Data/Suffix
Prefix/Data/ Suffix
Data/Suffix
Prefix
STX (1003)
None
STX (1002)
None
Suffix
ETX (1002)
CR (1013)
CR (1013) ETX (1003)
CR (1013)
The CUTE host disables all parameter scanning, including Set Defaults. If you inadvertently select CUTE, scan Enable Parameter Barcode Scanning, and then change the host selection.