Setting the Power Failure Recovery Mode Jumper

Setting the Power Failure Recovery Mode Jumper

The printer can be configured to restart itself after a power failure, unattended, with the Power Failure Recovery Mode set.
  • Remove the power supply cable from the back of the printer.
  • Remove any attached printer interface cables.
The Power Failure Recovery Mode is only available on printers with a Printer Connectivity Module installed in the printer.
The Printer Connectivity Modules have a Power Failure Recovery jumper set to OFF. With the jumper set to ON, the printer will automatically Power ON when plugged into an active (ON) AC power source.
  1. Remove the module access door and connectivity module. See Configuring Wired Connectivity Options and Power Failure Recovery Mode for 'Removing a Connectivity Module Card' instructions.
  2. Move the AUTO (Power Failure Recovery Mode) jumper from the OFF position to the ON.
  3. Reinstall the connectivity module and module access door. See Configuring Wired Connectivity Options and Power Failure Recovery Mode for 'Installing a Connectivity Module Card' instructions.