Connecting to a Sinking Input Using an External Pull Up Resistor
Connecting to a Sinking Input Using an External Pull Up Resistor
Add a pull-up resistor to ensure proper voltage levels when connecting to a sinking input.
Connect an auxiliary output signal to a sinking input to preserve the three available output signals.
An external pull-up resistor is required for this configuration.
The scanner's auxiliary output signals can sink up to 50 mA. Use the documentation of your sinking device to calculate the required resistance for your external pull-up resistor (if necessary).