Use the following table to estimate how long a scanner will scan before entering into power-saving mode.
Beaconing and scanning both use battery power. The following table shows how well the battery performs when the battery threshold (parameter 2407) is set to the default value of 37% at various temperatures. These results were calculated assuming:
use of an extended battery
beginning the shift with a fully charged battery
scanning with a 100% success rate
Scans per Minute
Room Temperature
-20°C
-30°C
8
Exceeds
Exceeds
Meets Marginally
10
Meets Easily
Exceeds
Meets Marginally
12
Meets Easily
Meets Easily
Meets Marginally
16
Meets Marginally
Meets Marginally
Meets Marginally
A battery beacons for a minimum of 48 hours before fully drains. The beaconing battery life is calculated assuming:
beaconing occurs within the operating temperature of the scanner