Unsolicited Heartbeat Interval

Unsolicited Heartbeat Interval

Parameter #
1118
(SSI # F8h 04h 5Eh)
When this parameter is enabled, the scanner can send unsolicited heartbeat messages to assist in diagnostics. The range is 0 - 9999.
The heartbeat event is sent as decode data (with no decode beep) in the form of:
MOTEVTHB:nnn
Where:
nnn
is a three-digit sequence number starting at 001 and wrapping after 100.
Scan Disable Unsolicited Heartbeat Interval to turn off the feature.