This table provides troubleshooting options for the cradle.
Problem
Cause
Solution
The device Charge LED indicator does not light when the device is inserted.
The cradle is not receiving power.
Replace the device in the cradle. Go to
Settings
About phone
Battery Information
Charge Status
to view battery status.
The battery is faulty.
Verify that other batteries charge properly. If so, replace the faulty battery.
The device is not inserted correctly in the cradle.
Remove the device and reinsert it correctly. Verify charging is active. Go to
Settings
About phone
Battery Information
Charge Status
to view battery status.
The ambient temperature of the cradle is too warm.
Move the cradle to an area where the ambient temperature is between 0°C (32°F) and 35°C (95°F).
The device Charge LED indicator is a fast-blinking red when the device is inserted.
The ambient temperature of the cradle is too low or too high.
Move the cradle to an area where the ambient temperature is between 0°C (32°F) and 35°C (95°F).
Charging has gone on too long without completion (typically eight hours).
Verify that other batteries charge properly. If so, replace the faulty battery.
The spare Battery Charging LED does not light when the spare battery is inserted.
The spare battery is not correctly seated.
Remove and re-insert the spare battery into the cradle, ensuring it is seated correctly.
The spare battery is not charging.
The battery is not fully seated in the charging slot.
Remove and re-insert the spare battery into the cradle, ensuring it is correctly seated.
The battery was inserted incorrectly.