USB Charge Cable Troubleshooting

USB Charge Cable Troubleshooting

This table provides troubleshooting options for the USB Charge Cable.
Symptom
Possible Cause
Action
The device Charge LED indicator does not light when the device is attached.
The cable is not receiving power.
Ensure the power cable is connected securely to both the cable and to AC power.
The device is not seated correctly in the cable cup.
Remove and re-insert the device into the cable cup, ensuring it is correctly seated.
The device battery is not charging.
The device was detached from the cable, or the cable was unplugged from AC power too soon.
Ensure cable is receiving power. Ensure device is seated correctly.
The 7,000 mAh PowerPrecision+ extended battery charges from 0% to 90% in less than 5.2 hours at room temperature.
The 5,200 mAh PowerPrecision+ high capacity battery charges from 0% to 90% in less than 3.8 hours at room temperature.
The battery is faulty.
Verify that other batteries charge properly. If so, replace the faulty battery.
The device is not fully seated in the cable.
Remove and re-insert the device into the cradle, ensuring it is firmly seated.
During data communication, no data was transmitted, or transmitted data was incomplete.
The cable was disconnected from the device during communications.
Re-attach the cable and retransmit.
Incorrect cable configuration.
See the system administrator.
Communication software is not installed or configured properly.
See the system administrator.