1-Slot Cradle Only with Spare Battery Cradle Troubleshooting

1-Slot Cradle Only with Spare Battery Cradle Troubleshooting

The following table provides troubleshooting options for the cradle.
Troubleshooting the 1-Slot Cradle Only with Spare Battery Cradle
Symptom
Possible Cause
Action
LEDs do not light when the device is inserted.
Cradle is not receiving power.
Ensure the power cable is connected securely to the cradle and AC power.
Device is not seated firmly in the cradle.
Remove and re-insert the device into the cradle, ensuring it is firmly seated.
Device battery is not charging.
Device was removed from the cradle, or the cradle was unplugged from AC power too soon.
Ensure the cradle is receiving power. Ensure the device is seated correctly. Confirm main battery is charging. The standard battery charges from fully depleted to 80% in less than 1 hour and 20 minutes. The extended battery charges from fully depleted to 80% in less than 1 hour and 50 minutes.
Battery is faulty.
Verify that other batteries charge properly. If so, replace the faulty battery.
Device is not fully seated in the cradle.
Remove and re-insert the device into the cradle, ensuring it is firmly seated.
Extreme battery temperature.
Battery does not charge if the ambient temperature is below 5°C (41°F) or above 40°C (104°F).
Spare battery is not charging.
Battery is not fully seated in the charging slot.
Remove and re-insert the spare battery in the cradle, ensuring it is firmly seated. The standard battery charges from fully depleted to 80% in less than 1 hour and 20 minutes. The extended battery charges from fully depleted to 80% in less than 1 hour and 50 minutes.
Battery was inserted incorrectly.
Re-insert the battery so the charging contacts on the battery align with the contacts on the cradle.
Battery is faulty.
Verify that other batteries charge properly. If so, replace the faulty battery.