Configuration Setting to Command Cross-reference

Configuration Setting to Command Cross-reference

The Printer Configuration Report, shown below, provides a listing of a majority of the configurations settings that can be set by ZPL command.
The sensor settings shown in this image, for example, are used for service purposes.
ZPL Commands and Configuration Report Callout Cross-Reference
Command
Listing Name
Default (or description)
^SD
DARKNESS
10.0
DARKNESS SWITCH
LOW (Default), MEDIUM, or HIGH
^PR
PRINT SPEED
  • 152 mm/s / 6 ips (max.) - 203 dpi
  • 102 mm/s / 4 IPS (max.) - 300 dpi
^TA
TEAR OFF
+000
^MN
MEDIA TYPE
GAP/NOTCH
SENSOR SELECT
AUTO (
^MNA
- Auto-Detect)
^MT
PRINT METHOD
THERMAL-TRANS or DIRECT-THERMAL
^PW
PRINT WIDTH
448 (dots for 203 dpi) or 640(dots for 300 dpi)
^LL
LABEL LENGTH
1225 (dots) (dynamically updated while printing)
^ML
MAXIMUM LENGTH
989 mm (39.0 in.)
USB COMM.
(Connection Status: Connected / Not Connected)
^SCa
BAUD
9600
^SC,b
DATA BITS
8 BITS
^SC,,c
PARITY
NONE
^SC,,,,e
HOST HANDSHAKE
AUTO
^SC,,,,,f
PROTOCOL
NONE
— SGD —**
COMMUNICATIONS
NORMAL MODE
^CT / ~CT
CONTROL CHAR
<~> 7EH
^CC / ~CC
COMMAND CHAR
<^> 5EH
^CD / ~CD
DELIM./CHAR
<,> 2CH
^SZ
ZPL MODE
ZPL II
— SGD —
COMMAND OVERRIDE
Not supported with a ZPL command. Uses the Set-Get-Do command listed in the ZPL manual. (See device.command_override.xxxxx in the ZPL Programming Guide.)
INACTIVE
^MFa
MEDIA POWER UP
NO MOTION
^MF,b
HEAD CLOSE
FEED
~JS
BACKFEED
DEFAULT
^LT
LABEL TOP
+000
^^LS
LEFT POSITION
+0000
~JD / ~JE
HEXDUMP
NO (~JE)
REPRINT MODE
DISABLED
From this point in the Configuration Receipt listing, the printout lists sensor settings and values which can be used to troubleshoot sensor and media operations. These are typically used by Zebra Tech Support to diagnose printer problems.
The configuration settings listed here resume after the TAKE LABEL sensor value. This listing includes commands that are:
  • used to generate status information, or
  • relate to printer features whose settings are seldom changed from their defaults.
ZPL Commands and Configuration Receipt Callout Cross-Reference
Command
Listing Name
Description
^MP
MODES ENABLED
Default: CWF (See
^MP
Command)
MODES DISABLED
(No default set)
^JM
RESOLUTION
Default: 448 8/mm (203 dpi); 640 8/mm (300 dpi)
FIRMWARE
Lists ZPL Firmware Version
XML SCHEMA
1.3
HARDWARE ID
Lists Firmware Boot-block Version
LINK-OS VERSION
CONFIGURATION
CUSTOMIZED (after first use)
RAM
2104k........ R:
ONBOARD FLASH
6144k.........E:
^MU
FORMAT CONVERT
NONE
RTC DATE
Date Displayed
RTC TIME
Time Displayed
^JI / ~JI
ZBI
DISABLED (Requires key to enable)
ZBI VERSION
2.1 (Displayed if installed)
ZBI STATUS
READY
^JH
^MA
~RO
LAST CLEANED
X,XXX IN
HEAD USAGE
X,XXX IN
TOTAL USAGE
X,XXX IN
RESET CNTR1
X,XXX IN
RESET CNTR2
X,XXX IN
NONRESET CNTR0 (1, 2)
X,XXX IN
RESET CNTR1
X,XXX IN
RESET CNTR2
X,XXX IN
NONRESET CNTR0 (1, 2)
X,XXX IN
RESET CNTR1
X,XXX IN
RESET CNTR2
X,XXX IN
SLOT1
EMPTY / SERIAL / WIRED
MASS STORAGE COUNT
0
HID COUNT
0
USB HOST LOCK OUT
OFF / ON
SERIAL NUMBER
XXXXXXXXXXX
^JH
EARLY WARNING
MAINT. OFF
The printer can set a command or a group of commands at one (1) time for all receipts or labels that follow. Those settings remain in effect until:
  • they are changed by subsequent commands
  • the printer is reset, or
  • you restore the printer to its factory defaults.