TCP/IP Settings
TCP/IP Settings

TCP/IP Settings

Configure TCP/IP settings, such as enabling TCP.IP Control, selecting a port number, selecting a terminator, or setting a trigger string.
TCP/IP Settings
Setting
Description
Enable TCP/IP Control
Enabling the TCP/IP control interface allows the device to receive triggers over a TCP/IP connection.
It is recommended to disable this interface when not in use.
Control Port Number
Select a port number that accepts ASCII command strings for the device.
Control Terminator
Select a terminator that follows the incoming ASCII command string.
Trigger String
Set a customizable trigger command. Sending this string to the Control Port with the Control Terminator triggers the deployed job on the camera when TCP/IP trigger is selected in the Capture chevron.
Enable TCP/IP Results
Enabling the TCP/IP Results interface allows the device to output result data over a TCP/IP connection.
It is recommended to disable this interface when not in use.
Connection Type
The Server Host system attaches to the device on the Result Port Number. The data is sent out with the Results Terminator. The device connects to a host system when the Client is enabled at the specified IP address. Port Number uses Result Terminator to send the data packet.
IP Address
If the Connection Type is set to Client, enter the IP address.
Results Port Number
When in Server mode, the port that the device sends the data out on.
When in Client mode, the port on the device's host system connects to.
Results Terminator
For both Client and Server modes, the Results Terminator is the termination text of the string data package. The default setting is CR+LF.
Timeout
When in Client mode, the time the device attempts to connect to the host system.
Enable TCP/IP Heartbeat
When enabled, this setting prompts the device to send out a heartbeat message at the defined interval to the connected TCP result host. The host uses this heartbeat message to verify that the connection with the device is active.
This setting only sends out a heartbeat message while a job is deployed. The heartbeat stops when the device is in Edit mode and resets after each TCP/IP output.
Heartbeat Interval
Set the heartbeat time interval.
Heartbeat Sequence