2-Slot Device/RS6000 Charging Cradle
2-Slot Device/RS6000 Charging Cradle

2-Slot Device/RS6000 Charging Cradle

Troubleshooting the 2-Slot Device/RS6000 Charging Cradle
Symptom
Possible Cause
Action
LEDs do not light when device or scanner is inserted.
Cradle is not receiving power.
Ensure the power cable is connected securely to both the cradle and to AC power.
Device is not seated firmly in the cradle.
Remove and re-insert the device into the cradle, ensuring it is firmly seated.
Scanner is not seated firmly in the cradle.
Remove and re-insert the scanner into the charging slot, ensuring it is firmly seated.
Device battery is not charging.
Device was removed from cradle or cradle was unplugged from AC power too soon.
Ensure cradle is receiving power. Ensure device is seated correctly. Confirm main battery is charging. The standard battery charges from fully depleted to 90% in approximately 4 hours, and the extended battery charges from fully depleted to 90% in approximately 5.5 hours.
Battery is faulty.
Verify that other batteries charge properly. If so, replace the faulty battery.
The device is not fully seated in the cradle.
Remove and re-insert the device into the cradle, ensuring it is firmly seated.
Extreme battery temperature.
Battery does not charge if ambient temperature is below 0°C (32°F) or above 40°C (104°F).
Scanner battery is not charging.
Scanner was removed from cradle or cradle was unplugged from AC power too soon.
Ensure cradle is receiving power. Ensure scanner is seated correctly. Confirm main battery is charging.
Battery is faulty.
Verify that other batteries charge properly. If so, replace the faulty battery.